UBIQUITI UniFi Access Door Hub (UA-Hub-Door)

SKU: UBNT UA-Hub-Door
5 People watching this product now!
  • Store Collection

Timing : 10 am to 9.00 pm (Monday to Saturday)

  • Free Delivery
  • (Order value AED 300 or above)

1-2 Working Days

  • Warranty
  • Return Policy

Payment Methods:

UBIQUITI UniFi Access Door Hub (UA-Hub-Door)

Dimensions174.9 x 126 x 32.9 mm (6.9 x 5 x 1.3″)
Weight363 g (12.8 oz)
Enclosure materialPolycarbonate
Mounting materialPolycarbonate
Hardware
Networking interface(5) 10/100/1000 Base-T
Power methodPoE++
UL 294 Power-limited Class 2 PSU
UL 60950-1/62368-1 LPS/PS2 PSU
Max. power consumptionWithout PoE output: 30W
With PoE output: 50W
PoE input50V DC, 1A
PoE outputPoE passthrough, (4) PoE, 50V DC, total 20W
LEDsWhite/blue
Button(1) Factory-reset
Digital inputRequest to exit/request to enter/remote release/door position sensor
Dry output relayLock: 30V DC, 1A
Aux: 30V DC, 1A
Powered output relayLock: 12V DC, 1A
Aux: 12V DC, 0.33A
12V DC, 0.33A
Recommend max. cable length
18 AWG
UACC-Cable-DoorLockRelay length
20
AWG length
22
AWG length
24
AWG length
UA-Lock-Electric
(400mA)
100 m
(328 ft)
66 m
(217 ft)
42 m
(138 ft)
25 m
(82 ft)
UA-Lock-Magnetic-270kg
(800mA)
46 m
(151 ft)
30 m
(98 ft)
20 m
(66 ft)
12 m
(29 ft)
UA-Lock-Magnetic-540kg
(500mA)
80 m
(262 ft)
51 m
(167 ft)
32 m
(105 ft)
20 m
(66 ft)
Other locks
(1A)
36 m
(118 ft)
24 m
(79 ft)
15 m
(49 ft)
9 m
(30 ft)
PoE cabling requirementsCable 5e cabling is the minimum performance category recommended. The performance category utilized should match the transmission speed required at the installation site.
The minimal conductor gauge permitted to connect between the PSE or power injector and the PD shall be 26 AWG (0.13 mm 2 ) for patch cords; 24 AWG (0.21 mm 2 ) for horizontal or riser cable.
Operating environmentIndoor use only
Ambient operating temperature0 to 40° C (32 to 104° F)
Ambient operating humidity5 to 95% noncondensing
UL 294 levelDestructive attack: Level I
Line security: Level I
Endurance: Level I
Standby power: Level I
UL 294 statementCompliance with IEEE 802.3 (at or af) specifications was not verified as part of UL 294.
The equipment is intended to comply with the section of the National Electrical Code, ANSI/NFPA 70, Article 725.121, Power Sources for Class 2 and Class 3 Circuits.
CAN/ULC-60839-11-1 GradeGrade assignment: 1
CertificationsCE, FCC, IC, UL 294, CAN/ULC-60839-11-1
Document number, and issue date and/or revision levelUA-Hub-Door002, V01

When you place an order with us at www.altahericomputers.com, we will do our best to get your items shipped to you as soon as possible.

We currently ship only within UAE.

ONLY UAE ISSUED CARDS ARE ACCEPTED.